The IRC and residential portion of the 2009 IBC define Type II handrail as follows:
Type II. Handrails with a perimeter greater than 6¼ inches (160 mm) shall provide a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for at least 3/8 inch (10mm) to a level that is not less than 1¾ inches (45 mm) below the tallest portion of the profile. The minimum width of the handrail above the recess shall be 1¼ inches (32 mm) to a maximum of 2¾ inches (70 mm). Edges shall have a minimum radius of 0.01 inch (0.25 mm).
Handrails are located at a height between 34" (864 mm) and 38" (965 mm). In areas where children are the principal users of a building or facility, the 2004 ADAAG recommends that a second set of handrails at a maximum height of 28" (711 mm) measured to the top of the gripping surface from the ramp surface or stair nosing can assist in preventing accidents.
|
|